UPS SYSTEMS

SMART BX

Online UPS

10 – 120 kVA 
High Effiency

With Innovative 3 Level Technology one of the highest level energy efficiencies in the industry.

Thanks to high efficiency up to 96%:

Less energy consumption to supply the loads.

Reduced energy loss.

Reduced electricity usage and air conditioning requirements. Reduction in operating cost of UPS.

Lowest Total Cost of Ownership

GBT based power factor correction technology provides input power factor close to 1 (≥ 0,99).

The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.

Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.

Maximum Availability

Parallel configuration up to 8 units per redundancy (N+1) and power increase.

Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.

Flexibility

External battery cabinets for different sizes of batteries to provide extended runtimes.

Different sizes of 10-40kVA cabinets for larger capacity of internal batteries when long autonomy times are required.

3/1 Phase version is available for 10-30kVA power ratings.

Frequency converter mode. Isolation transformers to vary neutral connectivity in the event of separate power sources or for galvanic isolation between input and output.

Compatible version with EN 50171 for supplying power to emergency lighting systems.

High Efficiency & Low Total Cost of Ownership
  • Reduced energy loss.
  • Reduced electricity usage and air conditioning requirements.
  • Less energy consumption to supply the loads thanks to high efficiency up to 96%.
  • Reduction in operating cost of UPS.
  • IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.
  • Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.
  • Small footprint and easy maintenance.
High Output Power Factor 1
  • Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS.
  • Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation).
  • No reduction in active power from 0,9 leading to 0,9 lagging.
Maximum Availability
  • Parallel configuration up to 8 units per redundancy (N+1) and power increase.
  • Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.
Standard Electrical Features
  • Dual Input.
  • Common Battery.
  • Backfeed Protection.
  • Cold Start (Optional).
  • Advanced Battery Management.
  • Short Circuit and Overload Protection.
  • Parallel Ready.
  • Redundant Power Supply.
  • Power Walk-in for Progressive Rectifier Start-up when the
  • Mains is Restored.
  • Battery Temperature Sensor.
  • Static and Manual Bypass Operation
Advanced Communication Features
  • 500 Real Time Event Log with Detailed Parameters.
  • User Friendly Multilingual 320×240 Graphic Display Provides.
  • Operation Information.
  • Monitoring and Shutdown Software.
  • RS232 Serial and RS485 Ports.
  • Modbus RTU (Optional).
  • 2 Communication Slots.
  • Remote Emergency Power Off (Optional).
  • Remote Display Panel (Optional).
  • Dry Contact (Optional).
  • SNMP (Optional).
  • ProfiBUS (Optional).
Flexibility
  • Temperature sensor for external battery cabinets for extended runtimes.
  • External battery cabinets for different sizes of batteries to provide extended runtimes.
  • Different sizes of 10-40kVA cabinets for larger capacity of internal batteries when long autonomy times are required.
  • 3/1 Phase version is available for 10-30kVA power ratings Frequency converter mode.
  • Isolation transformers to vary neutral connectivity in the event of separate power sources or for galvanic isolation between input and output.
  • Compatible version with EN 50171 for supplying power to emergency lighting systems.

Product Data sheet

Smart BX 10 – 120 KVA

User Manual

Smart BX 10 – 20 KVA

User Manual

Smart BX 30 – 60 KVA

User Manual

Smart BX 80 – 120 KVA

UPS SYSTEMS

Monophase and Threephase Uninterruptible Power Supplies.

With its expertise over 40 years of power protection, Ensmart offers a wide range of single phase and three phase UPS systems from 600VA up to 8MW. Our solutions provides clean and uninterruptible power for various applications from Personal computers to IT, Medical, Telecom and Industrial Applications. Please do not hesitate to contact us to help you to find the right solution for your home or business.